{"id":4188,"date":"2023-02-21T09:38:00","date_gmt":"2023-02-21T09:38:00","guid":{"rendered":"https:\/\/stark-water.com\/?p=4188"},"modified":"2025-07-14T14:59:56","modified_gmt":"2025-07-14T14:59:56","slug":"ten-major-faults-and-maintenance-methods-of-reverse-osmosis-equipment","status":"publish","type":"post","link":"https:\/\/stark-water.com\/id\/blog\/ten-major-faults-and-maintenance-methods-of-reverse-osmosis-equipment\/","title":{"rendered":"Sepuluh kesalahan utama dan metode perawatan peralatan reverse osmosis"},"content":{"rendered":"<p><span style=\"vertical-align: inherit;\"><span style=\"vertical-align: inherit;\"><span style=\"vertical-align: inherit;\"><span style=\"vertical-align: inherit;\"><span style=\"vertical-align: inherit;\"><span style=\"vertical-align: inherit;\"><span style=\"font-size:20px;\"><span style=\"font-family:Arial,Helvetica,sans-serif;\">Ten major faults and maintenance methods of RO reverse osmosis equipment<\/span><\/span><\/p>\n<p><span style=\"font-size:18px;\"><span style=\"font-family:Arial,Helvetica,sans-serif;\"><span style=\"color:#3498db;\">A. The switch is turned on, but the device does not start:<\/span><\/span><\/span><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Arial,Helvetica,sans-serif;\">1. Electrical circuit failure, such as insurance failure, wire falling off<br \/>\n2. The thermal protection element is not reset after protection<\/span><\/span><\/p>\n<p><span style=\"font-size:18px;\"><span style=\"font-family:Arial,Helvetica,sans-serif;\">Solusi:<\/span><\/span><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Arial,Helvetica,sans-serif;\">1. The waterway is undervoltage, check the insurance, check the wiring everywhere<br \/>\n2. Thermal protection element reset<br \/>\n3. Check the waterway and ensure the water supply pressure<\/span><\/span><\/p>\n<p><span style=\"color:#3498db;\"><span style=\"font-size:18px;\"><span style=\"font-family:Arial,Helvetica,sans-serif;\">B. After the equipment is started, the water inlet solenoid valve is not opened:<\/span><\/span><\/span><br \/>\n<span style=\"font-family:Arial,Helvetica,sans-serif;\"><span style=\"font-size:16px;\">1. Wiring off<br \/>\n2. Internal mechanical failure of the solenoid valve<br \/>\n3. Solenoid valve coil is broken<\/span><\/span><\/p>\n<p><span style=\"font-family:Arial,Helvetica,sans-serif;\"><span style=\"font-size:16px;\"><span style=\"font-size:18px;\">Solusi:<\/span><br \/>\n1. Check the wiring<br \/>\n2. Disassemble the solenoid valve for maintenance<br \/>\n3. Repair or replace the coil<\/span><\/p>\n<p><span style=\"color:#3498db;\"><span style=\"font-size:18px;\">C. The pump is running, but the rated pressure and flow cannot be reached:<\/span><\/span><br \/>\n<span style=\"font-size:16px;\">1. Pump reverse<br \/>\n2. The security filter element is dirty<br \/>\n3. There is air in the pump<br \/>\n4. The flush solenoid valve opens<\/span><\/p>\n<p><span style=\"font-size:18px;\">Solusi: &nbsp;<\/span><br \/>\n<span style=\"font-size:16px;\">1. Rewire<br \/>\n2. Clean or replace the filter element<br \/>\n3. Remove the air in the pump<br \/>\n4. Adjust the pressure after flushing<\/span><\/p>\n<p><span style=\"color:#3498db;\"><span style=\"font-size:18px;\">D. When the system pressure rises, the pump noise is loud<\/span><\/span><br \/>\n<span style=\"font-size:16px;\">1. Raw water flow is not enough<br \/>\n2. Raw water flow is unstable<\/span><\/p>\n<p><span style=\"font-size:18px;\">Solusi: &nbsp;<\/span><br \/>\n<span style=\"font-size:16px;\">1. Check the raw water pump and pipeline<br \/>\n2. Check the raw water pump and pipeline, and check whether there is leakage in the pipeline<\/span><\/p>\n<p><span style=\"color:#3498db;\"><span style=\"font-size:18px;\">E. The solenoid valve is not closed after flushing<\/span><\/span><br \/>\n<span style=\"font-size:16px;\">1. Solenoid valve control element and circuit failure<br \/>\n2. Solenoid valve mechanical failure<\/span><\/p>\n<p><span style=\"font-size:18px;\">Solusi:<\/span><br \/>\n<span style=\"font-size:16px;\">1. Check or replace components and lines<br \/>\n2. Disassemble the solenoid valve, repair or replace it<\/span><\/p>\n<p><span style=\"color:#3498db;\"><span style=\"font-size:18px;\">F. Undervoltage shutdown<\/span><\/span><br \/>\n<span style=\"font-size:16px;\">1. Insufficient supply of raw water<br \/>\n2. The filter element of the security filter is clogged<br \/>\n3. Improper pressure adjustment and underpressure caused by automatic flushing<\/span><\/p>\n<p><span style=\"font-size:18px;\">Solusi:<\/span><br \/>\n<span style=\"font-size:16px;\">1. Check whether the raw water pump and pre-treatment system are working<br \/>\n2. Clean and replace the filter element 3. Adjust the system pressure to the best state to keep the filtered pressure above 20psi<\/p>\n<p><span style=\"color:#3498db;\">G. The concentrated water pressure cannot reach the rated value<\/span><br \/>\n1. Pipeline leaks<br \/>\n2. The flushing solenoid valve is not fully closed<br \/>\n3. Recovery system leakage<\/span><\/p>\n<p><span style=\"font-size:18px;\">Solusi:<\/span><br \/>\n<span style=\"font-size:16px;\">1. Check and repair the pipeline<br \/>\n2. Check and replace the flushing solenoid valve<br \/>\n3. Check and repair the recovery system<\/span><\/p>\n<p><span style=\"color:#3498db;\"><span style=\"font-size:18px;\">H. The pressure is sufficient, but the pressure display is not in place<\/span><\/span><br \/>\n<span style=\"font-size:16px;\">1. Foreign matter in the pressure gauge hose is blocked<br \/>\n2. There is air in the hose<br \/>\n3. Pressure gauge failure<\/span><\/p>\n<p><span style=\"font-size:18px;\">Solusi:<\/span><br \/>\n<span style=\"font-size:16px;\">1. Check and clear the pipeline<br \/>\n2. Remove air<br \/>\n3. Replace the pressure gauge<\/span><\/p>\n<p><span style=\"color:#3498db;\"><span style=\"font-size:18px;\">I. Poor water quality<\/span><\/span><br \/>\n<span style=\"font-size:16px;\">1. Membrane fouling and scaling<br \/>\n2. Membrane junction head seal aging failure<\/span><\/p>\n<p><span style=\"font-size:18px;\">Solusi:<\/span><br \/>\n<span style=\"font-size:16px;\">1. Chemical cleaning according to technical requirements<br \/>\n2. Replace the O-ring<br \/>\n3. Replace the membrane<\/span><\/p>\n<p><span style=\"color:#3498db;\"><span style=\"font-size:18px;\">J. Production decline<\/span><\/span><br \/>\n<span style=\"font-size:16px;\">1. Membrane fouling, fouling, chemical cleaning according to technical requirements<br \/>\n2. The change of water temperature is recalculated according to the actual water temperature to determine the production water.<br \/>\n<a href=\"https:\/\/stark-water.com\/id\/\">BACK<\/a><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>Sepuluh kesalahan utama dan metode perawatan peralatan reverse osmosis, Klik untuk mengetahui lebih lanjut,<\/p>","protected":false},"author":1,"featured_media":4189,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1],"tags":[],"class_list":["post-4188","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-water-treatment-industry-information"],"acf":[],"_links":{"self":[{"href":"https:\/\/stark-water.com\/id\/wp-json\/wp\/v2\/posts\/4188","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/stark-water.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/stark-water.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/stark-water.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/stark-water.com\/id\/wp-json\/wp\/v2\/comments?post=4188"}],"version-history":[{"count":0,"href":"https:\/\/stark-water.com\/id\/wp-json\/wp\/v2\/posts\/4188\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/stark-water.com\/id\/wp-json\/wp\/v2\/media\/4189"}],"wp:attachment":[{"href":"https:\/\/stark-water.com\/id\/wp-json\/wp\/v2\/media?parent=4188"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/stark-water.com\/id\/wp-json\/wp\/v2\/categories?post=4188"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/stark-water.com\/id\/wp-json\/wp\/v2\/tags?post=4188"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}