SWRO 8040 Low-Energy RO Membrane

SWRO 8040 low-energy seawater reverse osmosis membrane engineered to deliver similar productivity at lower operating pressure. Rated around 32,000 mg/L NaCl at 25 °C. Typical salt rejection up to 99.5% with a standard 1.125″ permeate tube for 8″ vessels.

商品説明

This 8.0″ × 40″ thin-film composite (TFC) RO膜 is designed for seawater systems that prioritize energy efficiency without compromising stable permeate quality. It is a drop-in replacement for standard 8040 pressure vessels and interconnectors, and includes clear operating limits, cleaning chemistry windows, and preservation guidance for dependable service life.

Key features

  • Low-energy design achieves target flux at reduced feed pressure to help lower kWh per m³.
  • Typical salt rejection up to 99.5% for dependable product conductivity.
  • Balanced feed spacers support stable differential pressure and effective CIP.
  • 1.125″ permeate tube ID; drop-in fit for multi-element 8040 vessels and couplers.
  • Compatible with energy recovery devices (ERD) and staged SWRO arrays.

Interfaces & compatibility

  • Format: 8040 TFC polyamide element
  • Permeate tube: 1.125″ (28.6 mm)
  • Housings/couplers: standard 8″ pressure vessels with interconnectors
  • Change-out: replace like-for-like in most 8040 trains

Operating & cleaning limits*

  • Max temperature: 45 °C (113 °F)
  • pH range (operation): 2–11; (cleaning): 1–12
  • Max pressure: 1,200 psi (8.3 MPa)
  • Free chlorine: not recommended on TFC unless explicitly allowed by the datasheet; dechlorinate upstream

*Always verify final limits on the current model datasheet.

Typical test conditions

32,000 mg/L NaCl25 °C, reduced operating pressure versus HR types, and ~8% recovery. In service, performance depends on temperature, salinity, recovery, and pretreatment (SDI/MFI, antiscalant window).

What’s included

  • Factory-preserved element in sealed bag
  • Installation torque notes; cleaning & preservation guidance (download)

製品パラメーター

技術パラメーター

Element size 8.0″ × 40″ (8040)
Active area ~37 m² (400 ft²), model dependent
Typical salt rejection up to 99.5% (datasheet dependent)
Rated permeate flow (window) ~34–38 m³/d (9,000–10,000 gpd) at reduced pressure
Permeate tube ID 1.125″ (28.6 mm)
Max operating pressure 1,200 psi (8.3 MPa)
Max temperature 45 °C (113 °F)
pH range 2–11 operation; 1–12 cleaning
Test conditions 32,000 mg/L NaCl; 25 °C; reduced pressure; ~8% recovery

Values shown are typical for listing; final selection should follow the current model datasheet.

適用業種

  • Municipal SWRO plants with energy-recovery devices
  • Retrofits where pump head is limited or energy savings are targeted
  • Coastal hotels, island resorts, and industrial SWRO requiring lower specific energy use

アドバンテージ・ワン

Advantage 1 — Lower pressure for the same output

The low-energy design helps achieve target flux at reduced feed pressure, supporting lower specific energy consumption and potentially extending high-pressure pump life when operated within recommended windows.

アドバンテージ2

Advantage 2 — Drop-in 8040 compatibility

Standard 1.125″ permeate tube and multi-element vessel coupling enable quick change-outs. Acceptance after start-up is straightforward: normalized permeate flow near the clean baseline, rejection on spec, and stage ΔP within limits.

関連商品

よくあるご質問

逆浸透膜システムの寿命は、水質とメンテナンスに左右されます。通常、膜は2~3年、システム自体は適切な手入れをすれば10年以上持ちます。

はい、当社のシステムはすべてフルカスタマイズが可能です。お客様のウォーターレポートとアプリケーションのニーズを分析し、オーダーメイドのソリューションを提供します。

当社の製品はCE、ISO 9001に準拠しており、ご要望に応じて特定の地域の規制や業界標準に適合するように設計することができます。

標準システムは7~15日以内に出荷される。カスタマイズされた注文の場合、リードタイムは複雑さによって20~25日に延びることがあります。

はい。完全な技術文書、ビデオによる遠隔指導を提供し、ご要望に応じてエンジニアを海外に派遣することも可能です。

お見積もりには、ROシステム一式、コントロールパネル、ポンプ、前処理ユニット、必要な付属品が含まれます。ご要望に応じて、設置用工具やスペアパーツも含まれます。