160 m³/h UF Water Purifier | Hollow Fiber Ultrafiltration | STARK
제품 설명
Each rack integrates backwash pumps, air scour and automated chemically enhanced backwash (CEB); periodic CIP (e.g., NaOCl/citric) restores permeability. The PLC sequences transmembrane pressure (TMP) limits, flux, backwash intervals and chemical dosing. Options include inline coagulation for difficult feeds, integrity testing, and UF→RO interlocks.
- Consistent filtrate SDI < 3 for RO pretreatment (when designed with inline coagulation/flux setpoints)
- Modular racks allow future capacity expansion beyond 160 m³/h
- Food-grade or industrial build; SS/UPVC wetted piping per duty
Note: Final design is engineered from feed turbidity/SDI, temperature and fouling indices. Pilot or jar-test data can be used to set flux, recovery and chemical regime.
제품 매개변수
Technical Parameters
Rated Capacity | 160 m³/h (continuous, configurable) |
---|---|
Membrane Type | Hollow fiber UF, PVDF or PES/PS, hydrophilic |
Pore Size (nominal) | ~0.01–0.03 μm |
Operation Mode | Dead-end with periodic backwash & air scour; CEB/CIP programmable |
Typical Flux | 60–120 L/m²·h (temperature & feed dependent) |
TMP Range | 0.05–0.25 MPa typical; max per module spec |
복구 | ~90–95% (accounting for backwash/CEB losses) |
Feed Water Limits | Turbidity ≤ 50 NTU typical (higher with coagulation); SDI < 8 recommended |
Backwash | Every 20–60 min; filtrate/air; 30–60 s cycles |
Chemicals | CEB/CIP: NaOCl, citric, NaOH (ranges per membrane OEM); pH 2–12 service |
Filtrate Quality | Low turbidity; bacteria removal to log levels typical of UF membranes |
Controls | PLC/HMI with TMP/flux control, integrity/pressure interlocks, data logging |
Materials | Skid SS304; process piping SS/UPVC/CPVC; instruments SS/PTFE seals |
Electrical | 380–415 V/50 Hz or 460 V/60 Hz; VFD pumps |
발자국 | Modular racks; layout per site & access aisles |
참고 | Values are typical; final BOM & guarantees confirmed after feed study. |
해당 산업
- Municipal water & groundwater plants — clarification & polishing
- Industrial RO pretreatment — stable SDI and biofouling control
- Bottled water & beverage — particulate removal and clarity
- Wastewater tertiary treatment & reuse — low-turbidity filtrate
- Desalination pretreatment — seawater/brackish UF before SWRO/ BWRO
- Surface water treatment — algae & pathogen barrier
장점 1
Advantage 1 — Stable Water Quality & RO-Ready
- UF barrier (~0.01–0.03 μm) for turbidity, colloids and most bacteria
- SDI control supports high RO uptime and longer membrane life
- Inline coagulation option for challenging surface waters
- Automatic integrity & pressure interlocks for safe operation
이점 2
Advantage 2 — Automated, Service-Friendly Operation
- PLC/HMI sequences backwash, air scour, CEB and CIP with recipes
- Modular racks, front access to pumps & valves for quick service
- VFD pumps optimize energy at variable flux and temperature
- Remote support & spare parts through STARK global network
관련 제품
연관 상품
자주 묻는 질문
Q1: 역삼투압 시스템의 수명은 얼마나 되나요?
역삼투압 시스템의 수명은 수질과 유지 관리에 따라 달라집니다. 일반적으로 멤브레인의 수명은 2~3년이며, 시스템 자체는 적절한 관리를 통해 10년 이상 지속될 수 있습니다.
Q2: 다양한 수질 조건에 따라 시스템을 맞춤 설정할 수 있나요?
예, 모든 시스템은 완벽하게 사용자 정의할 수 있습니다. 고객의 수질 보고서와 애플리케이션 요구 사항을 분석하여 맞춤형 솔루션을 제공합니다.
Q3: STARK 장비는 어떤 표준을 준수하나요?
당사의 제품은 CE, ISO 9001을 준수하며 요청에 따라 특정 지역 규정 또는 산업 표준을 충족하도록 설계할 수 있습니다.
Q4: STARK RO 시스템의 배송 시간은 어떻게 되나요?
표준 시스템은 7~15일 이내에 배송됩니다. 맞춤형 주문의 경우 복잡성에 따라 리드 타임이 20~25일로 연장될 수 있습니다.
Q5: 기술 지원이나 설치 안내를 제공하나요?
예. 전체 기술 문서와 비디오를 통한 원격 지원을 제공하며, 요청 시 엔지니어를 해외로 파견할 수 있습니다.
Q6: 견적에는 무엇이 포함되나요?