SWRO 8040 Low-Energy RO Membrane
SWRO 8040 low-energy seawater reverse osmosis membrane engineered to deliver similar productivity at lower operating pressure. Rated around 32,000 mg/L NaCl at 25 °C. Typical salt rejection up to 99.5% with a standard 1.125″ permeate tube for 8″ vessels.
제품 설명
This 8.0″ × 40″ thin-film composite (TFC) RO membrane is designed for seawater systems that prioritize energy efficiency without compromising stable permeate quality. It is a drop-in replacement for standard 8040 pressure vessels and interconnectors, and includes clear operating limits, cleaning chemistry windows, and preservation guidance for dependable service life.
Key features
- Low-energy design achieves target flux at reduced feed pressure to help lower kWh per m³.
- Typical salt rejection up to 99.5% for dependable product conductivity.
- Balanced feed spacers support stable differential pressure and effective CIP.
- 1.125″ permeate tube ID; drop-in fit for multi-element 8040 vessels and couplers.
- Compatible with energy recovery devices (ERD) and staged SWRO arrays.
Interfaces & compatibility
- Format: 8040 TFC polyamide element
- Permeate tube: 1.125″ (28.6 mm)
- Housings/couplers: standard 8″ pressure vessels with interconnectors
- Change-out: replace like-for-like in most 8040 trains
Operating & cleaning limits*
- Max temperature: 45 °C (113 °F)
- pH range (operation): 2–11; (cleaning): 1–12
- Max pressure: 1,200 psi (8.3 MPa)
- Free chlorine: not recommended on TFC unless explicitly allowed by the datasheet; dechlorinate upstream
*Always verify final limits on the current model datasheet.
Typical test conditions
32,000 mg/L NaCl, 25 °C, reduced operating pressure versus HR types, and ~8% recovery. In service, performance depends on temperature, salinity, recovery, and pretreatment (SDI/MFI, antiscalant window).
What’s included
- Factory-preserved element in sealed bag
- Installation torque notes; cleaning & preservation guidance (download)
For field criteria, see RO membrane replacement, cleaning & CIP, and troubleshooting matrix.
제품 매개변수
Technical Parameters
Element size | 8.0″ × 40″ (8040) |
---|---|
Active area | ~37 m² (400 ft²), model dependent |
Typical salt rejection | up to 99.5% (datasheet dependent) |
Rated permeate flow (window) | ~34–38 m³/d (9,000–10,000 gpd) at reduced pressure |
Permeate tube ID | 1.125″ (28.6 mm) |
Max operating pressure | 1,200 psi (8.3 MPa) |
Max temperature | 45 °C (113 °F) |
pH range | 2–11 operation; 1–12 cleaning |
Test conditions | 32,000 mg/L NaCl; 25 °C; reduced pressure; ~8% recovery |
Values shown are typical for listing; final selection should follow the current model datasheet.
해당 산업
- Municipal SWRO plants with energy-recovery devices
- Retrofits where pump head is limited or energy savings are targeted
- Coastal hotels, island resorts, and industrial SWRO requiring lower specific energy use
장점 1
Advantage 1 — Lower pressure for the same output
The low-energy design helps achieve target flux at reduced feed pressure, supporting lower specific energy consumption and potentially extending high-pressure pump life when operated within recommended windows.이점 2
Advantage 2 — Drop-in 8040 compatibility
Standard 1.125″ permeate tube and multi-element vessel coupling enable quick change-outs. Acceptance after start-up is straightforward: normalized permeate flow near the clean baseline, rejection on spec, and stage ΔP within limits.관련 제품
연관 상품
자주 묻는 질문
Q1: 역삼투압 시스템의 수명은 얼마나 되나요?
역삼투압 시스템의 수명은 수질과 유지 관리에 따라 달라집니다. 일반적으로 멤브레인의 수명은 2~3년이며, 시스템 자체는 적절한 관리를 통해 10년 이상 지속될 수 있습니다.
Q2: 다양한 수질 조건에 따라 시스템을 맞춤 설정할 수 있나요?
예, 모든 시스템은 완벽하게 사용자 정의할 수 있습니다. 고객의 수질 보고서와 애플리케이션 요구 사항을 분석하여 맞춤형 솔루션을 제공합니다.
Q3: STARK 장비는 어떤 표준을 준수하나요?
당사의 제품은 CE, ISO 9001을 준수하며 요청에 따라 특정 지역 규정 또는 산업 표준을 충족하도록 설계할 수 있습니다.
Q4: STARK RO 시스템의 배송 시간은 어떻게 되나요?
표준 시스템은 7~15일 이내에 배송됩니다. 맞춤형 주문의 경우 복잡성에 따라 리드 타임이 20~25일로 연장될 수 있습니다.
Q5: 기술 지원이나 설치 안내를 제공하나요?
예. 전체 기술 문서와 비디오를 통한 원격 지원을 제공하며, 요청 시 엔지니어를 해외로 파견할 수 있습니다.
Q6: 견적에는 무엇이 포함되나요?
견적에는 전체 RO 시스템, 제어판, 펌프, 전처리 장치 및 필요한 모든 피팅이 포함됩니다. 요청 시 설치 도구와 예비 부품도 포함될 수 있습니다.