Purificador de agua por ósmosis inversa 6000LPH, Equipo de tratamiento de agua por ósmosis inversa con control PLC
6000 LPH RO Water Purification System by STARK delivers stable, low-TDS process water for factories, bottling, and commercial buildings. Skid-mounted design with PLC/HMI, auto-flush, and safety interlocks. Recovery engineered to your feedwater. Request a tailored quote.
Descripción del producto
En 6000 LPH RO Water Purification System is engineered for continuous industrial service. Using reverse osmosis membranes, it removes dissolved salts, organics, and particles to produce consistent permeate for boiler make-up, ingredient water, and rinsing lines. A typical train combines multimedia and activated-carbon filtration, a 5 μm cartridge, a stainless-steel high-pressure pump, and automatic flush cycles to reduce fouling. PLC/HMI control with low-/high-pressure interlocks improves reliability and simplifies daily operation. Standard recovery is 60–65% and can be tuned to your feed TDS, SDI, and scaling index. Options include a VFD high-pressure pump, 2-pass RO or RO+EDI for ultra-low conductivity, UV/ozone post-treatment, a CIP package, and remineralization. The compact, skid-mounted layout reduces footprint and service time—helping you deploy a scalable, energy-aware industrial RO system across plants.
Designed for reliable, 24/7 operation, the STARK 6000 LPH RO system converts municipal or well water into consistently pure process water. A typical process train includes media filtration / activated carbon, cartridge filtration, high-pressure ROy automatic flush sequences to reduce fouling. The compact skid minimizes footprint while providing front-access to pumps, instrumentation, and membranes for fast service.
Why it works: Reverse osmosis uses a semi-permeable membrane to reject dissolved salts, organics, microorganisms, and particulates—delivering permeate that meets downstream needs (boiler makeup, ingredient water, rinsing, etc.). For most industrial sources, 60–65% recovery is a balanced starting point; higher or lower recovery can be engineered based on feed TDS, temperature, SDI, and scaling indices. (STARK provides on-request feedwater testing and sizing.)
Integration & scalability: The system supports options like VFD high-pressure pump, UV/ozone post-treatment, alkalinity re-mineralization, CIP package, or 2-pass RO / EDI when ultra-low conductivity is required. For multi-site rollouts, STARK offers global technical support and spares logistics through our RO product line.
Parámetros del producto
Rated Permeate | 6,000 L/h (configurable) |
---|---|
Recovery (single-pass) | 60–65% typical; engineered per feed TDS/SDI/LSI |
Salt Rejection | 96–99% (membrane-dependent) |
Pretreatment | Multimedia → Activated Carbon → 5 μm cartridge |
RO Membranes | 4″ or 8″ elements (brand per BOM) |
High-Pressure Pump | Stainless-steel multistage, VFD optional |
Control | PLC/HMI, auto-flush, low/high-pressure interlocks |
Electrical | 380–415 V/50 Hz or 460 V/60 Hz (site standard) |
Frame & Piping | Stainless-steel skid, SS/UPVC process lines |
Note: Final values are confirmed after feedwater analysis; STARK provides sizing and testing on request.
Industria aplicable
Food & Beverage — ingredient water, CIP make-up
Bottled Water / Beverage — product & rinse water
Pharma / Cosmetics / Lab — pre-polish for DI/EDI
Electronics & Metal Finishing — low-conductivity rinsing
Commercial & Institutional — hospitals, hotels, campuses
Boiler & Cooling Make-Up — scale/corrosion-controlled supply
Ventaja Uno
Advantage 1 — High-Efficiency, Service-Friendly
Compact skid with clear service access
Auto-flush & safety interlocks reduce fouling risk
VFD-ready high-pressure pump for energy optimization
Modular options: CIP, 2-pass, RO+EDI, UV/ozone, remineralization
Ventaja DOS
Advantage 2 — Consistent Quality & Expert Support
Stable permeate for critical processes
Engineered recovery to balance water cost vs. fouling
Global spares & remote guidance from STARK
Proven architecture for scalable deployments
Productos relacionados
Productos relacionados
- Sistema de ósmosis inversa
Stark Stainless Steel Filter Tank 500LPH reverse osmosis water filter system
Añadir al presupuesto - Sistema de ósmosis inversa
Stark small 250LPH reverse osmosis filtration system
Añadir al presupuesto
PREGUNTAS FRECUENTES
P1: ¿Cuánto dura el sistema de ósmosis inversa?
La vida útil de un sistema de ósmosis inversa depende de la calidad del agua y del mantenimiento. Normalmente, la membrana dura entre 2 y 3 años, mientras que el sistema en sí puede durar más de 10 años con los cuidados adecuados.
P2: ¿Se puede personalizar el sistema en función de las diferentes condiciones del agua?
Sí, todos nuestros sistemas son totalmente personalizables. Analizamos su informe de aguas y sus necesidades de aplicación antes de ofrecerle soluciones a medida.
P3: ¿Qué normas cumplen los equipos STARK?
Nuestros productos cumplen las normas CE e ISO 9001, y pueden diseñarse para cumplir normativas regionales o estándares industriales específicos si así se solicita.
P4: ¿Cuál es el plazo de entrega de los sistemas de ósmosis inversa STARK?
Los sistemas estándar se envían en un plazo de 7-15 días. Para los pedidos personalizados, el plazo de entrega puede prolongarse hasta 20-25 días en función de la complejidad.
P5: ¿Ofrecen asistencia técnica u orientación para la instalación?
Sí. Proporcionamos documentación técnica completa, asistencia remota por vídeo y podemos enviar ingenieros al extranjero si así se solicita.
P6: ¿Qué incluye su presupuesto?
Nuestro presupuesto incluye el sistema de ósmosis inversa completo, el panel de control, las bombas, las unidades de pretratamiento y todos los accesorios necesarios. Si lo desea, podemos incluir herramientas de instalación y piezas de repuesto.