최대 30% 할인 - 프로젝트 액셀러레이터가 출시되었습니다! 7월 31일 종료 내 제안 받기

전문적인 솔루션 제공

Stark 500LPH reverse osmosis pretreatment water filter system

Optimize your Reverse Osmosis system’s performance and lifespan with Stark Water’s 500LPH Reverse Osmosis Pretreatment Water Filter System. This comprehensive pretreatment water filter system efficiently removes sediment, chlorine, and hardness, safeguarding your RO membranes and ensuring consistent pure water output for commercial and industrial applications.

제품 설명

The longevity and efficiency of any Reverse Osmosis (RO) system are fundamentally dependent on the quality of its feed water. Without proper pre-treatment, RO membranes can quickly foul, scale, or become damaged, leading to costly downtime, frequent replacements, and diminished performance. The Stark Water 500LPH Reverse Osmosis Pretreatment Water Filter System is meticulously engineered to serve as the vital first line of defense, providing comprehensive and reliable conditioning for your RO feedwater.

The Critical Role of a Pretreatment Water Filter System for RO

Our 500LPH reverse osmosis pretreatment water filter system is specifically designed to prepare raw water for the delicate RO membranes. With a capacity of 500 liters per hour, it is ideally suited for small to medium-sized commercial and industrial RO plants. The primary goal of this pretreatment water filter system is to remove contaminants that could otherwise harm the RO membranes. These typically include:

  • Suspended Solids & Turbidity: Particles like sand, silt, and rust can physically abrade or clog membrane surfaces.
  • Chlorine & Chloramines: These disinfectants can chemically oxidize and irreversibly damage thin-film composite (TFC) RO membranes.
  • Hardness (Calcium & Magnesium): These minerals precipitate as scale on the membrane surface, severely reducing water flow and rejection rates.
  • Iron & Manganese: Can cause fouling and staining of membranes.
  • Organic Matter: Can lead to biological fouling or accumulation on the membrane.

By effectively tackling these issues upstream, our system ensures the RO membranes operate under optimal conditions, maximizing their efficiency and greatly extending their operational lifespan.

Comprehensive Multi-Stage Filtration and Conditioning

The STARK 500LPH reverse osmosis pretreatment water filter system typically incorporates a series of interconnected stages to provide thorough water conditioning:

  • Multi-Media Filtration: Often includes sand filters or multimedia filters to effectively remove larger suspended solids, turbidity, and sediment.
  • Activated Carbon Filtration: Essential for removing free chlorine, chloramines, organic compounds, unpleasant tastes, and odors, protecting the RO membranes from chemical oxidation.
  • Water Softening (Ion Exchange): If the raw water has significant hardness, an automatic water softener is integrated to remove calcium and magnesium ions, preventing scale formation on the RO membranes.
  • Anti-scalant Dosing: A chemical dosing system may be included to inject anti-scalant, further inhibiting scale precipitation on the membrane surface, especially for challenging water chemistries or high recovery rates.
  • Micron Cartridge Filtration: A final safety filter (e.g., 5-micron) removes any residual fine particulates that might have passed through previous stages, providing absolute protection for the RO membranes.

This integrated approach ensures robust protection and optimal performance for your downstream RO system, translating into consistent pure water output and reduced operational costs.

제품 매개변수

Stark Water’s 500LPH Reverse Osmosis Pretreatment Water Filter System is engineered for efficient and reliable RO feedwater conditioning. Here are its key technical specifications:

매개변수사양 / 사용자 지정 옵션
핵심 키워드 포커스pretreatment water filter system design and capabilities.
System Capacity500 Liters Per Hour (LPH) / 0.5 m³/hr / approx. 2.2 GPM. Customizable for other capacities.
애플리케이션Pre-treatment for Reverse Osmosis (RO) systems.
Typical Stages Included
  • Multi-Media Filter (Sand filter)
  • Activated Carbon Filter
  • Water Softener (optional, based on hardness)
  • Micron Cartridge Filter (e.g., 5 μm)
  • Anti-scalant Dosing System (optional)
Filter Tanks MaterialFRP (Fiber Reinforced Plastic) or Carbon Steel (lined) for larger units.
Control TypeAutomatic control valves (time-based or flow-based for filters/softeners) for backwash/regeneration. PLC control for comprehensive system automation.
Inlet Water RequirementsMunicipal Water, Well Water, Brackish Water (pre-filtration for various RO types).
Output Water Quality (to RO)SDI (Silt Density Index) < 3; Free Chlorine < 0.1 ppm; Hardness < 0.03 mg/L (as CaCO³ if softener is included); Turbidity < 1.0 NTU.
Operating PressureTypically 0.2 – 0.6 MPa (2 – 6 Bar / 29 – 87 PSI).
작동 온도5°C – 45°C (41°F – 113°F).
전원 공급 장치Single Phase 220V AC, 50/60Hz or 3 Phase 380V AC, 50/60Hz (for automatic valves, pumps, dosing systems).
Construction Materials (Piping)UPVC, HDPE, or Stainless Steel.
Dimensions (Approximate)Skid-mounted compact design (e.g., L 1500mm x W 700mm x H 1800mm for a typical 500LPH system).
CertificationDesigned to meet relevant industry standards.

해당 산업

Stark Water’s 500LPH Reverse Osmosis Pretreatment Water Filter System is a versatile and essential component for industrial and commercial sectors utilizing RO technology, where effective feedwater conditioning is critical. This pretreatment water filter system is ideal for:

  • Commercial & Industrial RO Systems (Small-to-Medium Scale): Providing comprehensive pre-treatment for RO plants used in bottled water production, beverage formulation, food processing, and general industrial process water.
  • Hotels & Resorts: Ensuring optimal performance and longevity of RO systems used for drinking water, laundry, and general utility water supply.
  • Laboratories & Research Facilities: Pre-treating water for RO systems that supply high-purity water for various lab operations and analytical instruments.
  • Hospitals & Clinics: Preparing water for RO systems used in laundries, kitchens, or non-critical applications where high-quality feedwater protects downstream equipment.
  • Schools & Educational Institutions: Pre-treating water for RO systems that provide purified drinking water for students and staff.
  • Boiler Feed Water Pre-treatment: Conditioning raw water before it enters RO systems, which then feed low to medium pressure boilers, preventing scaling and corrosion.
  • Cooling Tower Make-up Water: Pre-filtering water for RO systems used to treat make-up water for cooling towers, reducing mineral buildup and minimizing blowdown.
  • Car Washes & Vehicle Detailing: Pre-treating water for RO systems that produce spot-free rinse water, extending the life of RO membranes.
  • Agricultural & Horticultural (Specialized): Preparing water for RO systems used in hydroponics or specialized irrigation where precise water quality is essential.
  • Small-Scale Manufacturing: Pre-filtering water for RO systems used in specific production processes requiring purified water.

장점 1

Stark Water’s 500LPH Reverse Osmosis Pretreatment Water Filter System offers the significant advantage of enhanced RO membrane lifespan and optimized performance through comprehensive pre-treatment. This pretreatment water filter system meticulously removes critical foulants like suspended solids, chlorine, and hardness, which are the primary causes of RO membrane degradation and scaling. By safeguarding your valuable RO membranes from premature wear, it significantly extends their operational life, reduces the frequency of costly replacements, and minimizes maintenance needs for your entire RO system. This proactive protection ensures that your reverse osmosis system consistently operates at peak efficiency, delivering high-purity water with reliable contaminant rejection, translating into substantial long-term operational savings and uninterrupted water purification.

이점 2

Our 500LPH Reverse Osmosis Pretreatment Water Filter System provides the dual advantage of automated efficiency and significant cost savings for reliable RO feedwater. This comprehensive pretreatment water filter system incorporates automatic control valves for backwash and regeneration cycles (for media filters and softeners), minimizing manual intervention and reducing labor costs. By optimizing the RO feedwater quality, it allows your RO system to operate more efficiently, consuming less energy and requiring fewer chemical cleanings. This leads to a lower overall operational expenditure. The integrated and automated design ensures consistent feedwater quality to your RO system, preventing downtime and guaranteeing a steady supply of purified water, making it an economically advantageous and highly reliable solution for your commercial or industrial water treatment needs.

관련 제품

자주 묻는 질문

역삼투압 시스템의 수명은 수질과 유지 관리에 따라 달라집니다. 일반적으로 멤브레인의 수명은 2~3년이며, 시스템 자체는 적절한 관리를 통해 10년 이상 지속될 수 있습니다.

예, 모든 시스템은 완벽하게 사용자 정의할 수 있습니다. 고객의 수질 보고서와 애플리케이션 요구 사항을 분석하여 맞춤형 솔루션을 제공합니다.

당사의 제품은 CE, ISO 9001을 준수하며 요청에 따라 특정 지역 규정 또는 산업 표준을 충족하도록 설계할 수 있습니다.

표준 시스템은 7~15일 이내에 배송됩니다. 맞춤형 주문의 경우 복잡성에 따라 리드 타임이 20~25일로 연장될 수 있습니다.

예. 전체 기술 문서와 비디오를 통한 원격 지원을 제공하며, 요청 시 엔지니어를 해외로 파견할 수 있습니다.

견적에는 전체 RO 시스템, 제어판, 펌프, 전처리 장치 및 필요한 모든 피팅이 포함됩니다. 요청 시 설치 도구와 예비 부품도 포함될 수 있습니다.

선호 제품
Stark  500LPH reverse osmosis pretreatment water filter systemStark 500LPH reverse osmosis pretreatment water filter system
견적에 추가
위로 스크롤