160 m³/h UF-Wasserreiniger | Hohlfaser-Ultrafiltration | STARK

160 m³/h UF Water Purifier using hollow-fiber membranes for turbidity, colloids and bacteria removal before RO or as a standalone polishing step. Skid-mounted racks with PLC/HMI automate backwash, air scour and CEB. PVDF/PS membranes, outside-in or inside-out configuration; recovery up to 90–95% depending on feed quality.

Beschreibung des Produkts

Der STARK 160 m³/h ultrafiltration system delivers high and stable filtrate quality for municipal, industrial and reuse applications. Hollow-fiber UF with nominal pore size ~0.01–0.03 μm forms a physical barrier to suspended solids, algae, most bacteria and high-molecular organics while keeping operating pressure low.

Each rack integrates backwash pumps, air scour and automated chemically enhanced backwash (CEB); periodic CIP (e.g., NaOCl/citric) restores permeability. The PLC sequences transmembrane pressure (TMP) limits, flux, backwash intervals and chemical dosing. Options include inline coagulation for difficult feeds, integrity testing, and UF→RO interlocks.

  • Consistent filtrate SDI < 3 for RO pretreatment (when designed with inline coagulation/flux setpoints)
  • Modular racks allow future capacity expansion beyond 160 m³/h
  • Food-grade or industrial build; SS/UPVC wetted piping per duty

Anmerkung: Final design is engineered from feed turbidity/SDI, temperature and fouling indices. Pilot or jar-test data can be used to set flux, recovery and chemical regime.

Produkt-Parameter

Technical Parameters

Rated Capacity 160 m³/h (continuous, configurable)
Membrane Typ Hollow fiber UF, PVDF or PES/PS, hydrophilic
Pore Size (nominal) ~0.01–0.03 μm
Operation Mode Dead-end with periodic backwash & air scour; CEB/CIP programmable
Typical Flux 60–120 L/m²·h (temperature & feed dependent)
TMP Range 0.05–0.25 MPa typical; max per module spec
Erholung ~90–95% (accounting for backwash/CEB losses)
Feed Water Limits Turbidity ≤ 50 NTU typical (higher with coagulation); SDI < 8 recommended
Backwash Every 20–60 min; filtrate/air; 30–60 s cycles
Chemikalien CEB/CIP: NaOCl, citric, NaOH (ranges per membrane OEM); pH 2–12 service
Filtrate Quality Low turbidity; bacteria removal to log levels typical of UF membranes
Kontrolliert PLC/HMI with TMP/flux control, integrity/pressure interlocks, data logging
Materials Skid SS304; process piping SS/UPVC/CPVC; instruments SS/PTFE seals
Elektrisch 380–415 V/50 Hz or 460 V/60 Hz; VFD pumps
Fußabdruck Modular racks; layout per site & access aisles
Anmerkungen Values are typical; final BOM & guarantees confirmed after feed study.

Anwendbare Industrie

  • Municipal water & groundwater plants — clarification & polishing
  • Industrial RO pretreatment — stable SDI and biofouling control
  • Bottled water & beverage — particulate removal and clarity
  • Wastewater tertiary treatment & reuse — low-turbidity filtrate
  • Desalination pretreatment — seawater/brackish UF before SWRO/ BWRO
  • Surface water treatment — algae & pathogen barrier

Vorteil Eins

Advantage 1 — Stable Water Quality & RO-Ready

  • UF barrier (~0.01–0.03 μm) for turbidity, colloids and most bacteria
  • SDI control supports high RO uptime and longer membrane life
  • Inline coagulation option for challenging surface waters
  • Automatic integrity & pressure interlocks for safe operation

Vorteil ZWEI

Advantage 2 — Automated, Service-Friendly Operation

  • PLC/HMI sequences backwash, air scour, CEB and CIP with recipes
  • Modular racks, front access to pumps & valves for quick service
  • VFD pumps optimize energy at variable flux and temperature
  • Remote support & spare parts through STARK global network

Verwandte Produkte

FAQ

Die Lebensdauer einer Umkehrosmoseanlage hängt von der Wasserqualität und der Wartung ab. In der Regel hält die Membran 2-3 Jahre, während das System selbst bei richtiger Pflege über 10 Jahre halten kann.

Ja, alle unsere Systeme sind vollständig anpassbar. Wir analysieren Ihren Wasserbericht und Ihren Anwendungsbedarf, bevor wir maßgeschneiderte Lösungen anbieten.

Unsere Produkte sind CE- und ISO 9001-konform und können auf Wunsch so gestaltet werden, dass sie spezifischen regionalen Vorschriften oder Industrienormen entsprechen.

Standardsysteme werden innerhalb von 7-15 Tagen ausgeliefert. Bei kundenspezifischen Aufträgen kann sich die Lieferzeit je nach Komplexität auf 20-25 Tage verlängern.

Ja. Wir bieten eine vollständige technische Dokumentation, eine Fernanleitung per Video und können auf Wunsch Techniker ins Ausland schicken.

Unser Angebot umfasst die komplette Umkehrosmoseanlage, die Schalttafel, die Pumpen, die Vorbehandlungseinheiten und alle erforderlichen Armaturen. Installationswerkzeuge und Ersatzteile können auf Anfrage mitgeliefert werden.

Bevorzugte Produkte
160m3h-uf-wasserreiniger-ro-behandlung-rack160 m³/h UF-Wasserreiniger | Hohlfaser-Ultrafiltration | STARK
- +
Zum Angebot hinzufügen
Nach oben scrollen