Ofrecerle una solución profesional

Century Egg Tratamiento de aguas residuales: Neutralice la salmuera de pH 14 con seguridad

Índice

century egg tratamiento de aguas residuales4

Century egg wastewater treatment deals with extremely caustic brine (often near pH 14), high salinity, suspended solids, proteins and oil/grease from washing and peeling. This guide explains two proven process trains, safe pH control, design ranges you can bench-test, and what to monitor from start-up to steady state.

Why Century Egg Wastewater Treatment Is Challenging

  • Very high pH from NaOH/Ca(OH)2 marinade — must be neutralized under control (never by dilution).
  • High salinity (brine) — osmotic stress inhibits anaerobic/aerobic biology if the strongest streams are not segregated.
  • Organics — proteins/peptides and marinade residues drive COD/BOD.
  • SS & FOG — shell fines and grease often require front-end clarification or DAF.
century egg wastewater treatment1
century egg wastewater treatment1

Century Egg Wastewater Treatment Process Options

Option 1 — pH Adjustment → Coag/Floc → Anaerobic → Aerobic → Clarification

  1. Equalization (EQ): buffer flows/loads; mixer + level control; conductivity probe recommended.
  2. Neutralization: acid dosing (HCl or food-grade CO2) with dual pH probes and interlocked pumps; target pH 6.8–7.5 before coagulation.
  3. Coagulation/Flocculation: PAC/FeCl3 + polymer; add DAF when FOG is high or quick solids capture is needed.
  4. Anaerobic (UASB/AnMBR): high-rate COD removal and biogas; keep feed salinity within acclimated limits.
  5. Aerobic polishing (A/O, SBR or MBR): close BOD/SS; nitrification if ammonia is present.
  6. Secondary Clarifier / Membrane: achieve solids limit; optional sand/carbon filters for final polishing.

Strengths: low OPEX (biogas credit), good for medium–large flows. Watch-outs: longer HRT, biology needs salinity control.

century egg wastewater treatment2
century egg wastewater treatment2

Option 2 — Brine Segregation Line + Physicochemical Mainstream + Aerobic MBR

  1. Brine-only line: collect the strongest marinade separately; do dedicated neutralization in a small, high-torque tank; controlled blending or partial desalination if TDS remains excessive.
  2. Mainstream line: wash water + light brine → neutralization → coag/floc → DAF.
  3. MBR: compact aerobic polishing with consistent low SS; no separate clarifier required.

Strengths: small footprint, faster start-up, robust to shift changes. Trade-off: higher CAPEX (membranes) and moderate OPEX.

ItemOption 1Option 2
FootprintMedium–largeSmall
Start-up SpeedSlower (seed/acclimation)Fast
Salinity ToleranceNeeds careful controlGood (split-stream)
OPEXLow (biogas credit)Medium

Safe Neutralization of pH-14 Brine

  • Instrumentation: dual pH probes (duty/standby), static or flash mixer, interlocked dosing pumps; high/low pH trips overflow back to EQ.
  • Acid choice: HCl is compact and precise; CO2 is safer and reduces overshoot (forms bicarbonate). Use corrosion-resistant materials and ventilation.
  • Control concept: coarse pH trim in EQ, fine trim in a dedicated neutralization tank just before coag/floc.
  • Safety: reaction is exothermic; add acid to water; provide secondary containment and eyewash/shower as standard EHS practice.

How to Estimate Acid Demand (Titration → Full-Scale)

  1. Take a well-mixed 1 L sample.
  2. Titrate with HCl of known normality to pH 7.0; record the volume used: V_HCl (litres).
  3. For 1.0 N HCl: acid equivalents per litre = V_HCl × 1.0.
  4. Per m³ requirement = (acid equivalents per litre) × 1000. If using 10 N HCl, divide the result by 10 to get litres per m³.

Worked example (step-by-step): A 1 L sample needs 0.20 L of 1.0 N HCl to reach pH 7.0.

Acid equivalents = 0.20 × 1.0 = 0.20 mol/L.
Per m³ = 0.20 × 1000 = 200 mol H⁺ equivalent.
Using 10 N HCl: volume per m³ = 200 ÷ 10 = 20 L/m³.
Add 10–20% control margin; let the PID loop fine-trim.

Note: If you need to convert a supplier’s mass-percent HCl to normality, use the SDS values for wt% y density.
Approximation for HCl (monoprotic): N ≈ (density × wt% × 10) / 36.46 (density in g/mL; wt% as %). Example: 31% HCl at 1.15 g/mL → N ≈ (1.15 × 31 × 10) / 36.46 ≈ 9.8 N.

Typical Design Ranges (Bench-Test Before Final Design)

  • EQ HRT: 6–12 h.
  • Coag/Floc: flash mix \(G·t\) ≈ 300–1000; floc \(G·t\) ≈ 20,000–80,000; optimize by jar tests.
  • DAF: surface loading \( \mathrm{SLR} = Q/A \) = 5–10 m³·m⁻²·h⁻¹; recycle 10–30%.
  • UASB/AnMBR: organic loading \( \mathrm{OLR} = Q \times \mathrm{COD}_{in}/V \) = 1–6 kg COD·m⁻³·d⁻¹; acclimate for salinity.
  • MBR: MLSS 6–12 g·L⁻¹; SRT 12–25 d; monitor TMP and set CIP triggers.
  • Final pH: typically 6–9; COD/BOD/SS to meet your permit or local Standard A/B equivalents.
century egg wastewater treatment3
century egg wastewater treatment3

Operation & Monitoring

  • Online: pH (dual), conductivity (salinity), DO in aerobic tanks, ORP in anaerobic, DAF interface level, MBR TMP.
  • Routine lab: COD, BOD5, SS, oil/grease; record chemical usage and sludge volumes.
  • Sludge: dewater (belt/plate); segregate brine-rich streams for licensed disposal.

PREGUNTAS FRECUENTES

Do we need a separate tank for the strongest brine?

Yes. Segregation protects biology from salt shock and significantly shortens the overall HRT. A small neutralization tank dedicated to the brine line is best practice.

HCl vs CO₂ — which is better for neutralization?

HCl offers tight control with a small footprint. CO₂ is inherently safer and reduces overshoot; many plants use CO₂ for bulk trim and a small HCl dose for precise setpoint control.

How do we choose between Option 1 and Option 2?

If land is available and long-term OPEX matters most, choose Option 1 with anaerobic energy recovery. If space is tight, flows vary or rapid commissioning is needed, Option 2 with brine split + MBR is preferred.

Engineering Notice (Read Before You Design)

Values above are typical ranges from bench practice. Always verify with titration, jar tests and, where feasible, a small pilot before full-scale design. Do not substitute dilution for treatment. Install dual pH probes, dosing interlocks, ventilation, secondary containment and eyewash/shower per standard EHS practice.

References & Further Reading

Comparte el post:
Productos preferidos
Scroll al inicio