SWRO 8040 High Rejection RO Membrane
SWRO 8040 high-rejection seawater reverse osmosis membrane for first-pass desalination. Rated around 32,000 mg/L NaCl at 25 °C with typical operating pressure near 800 psi. Typical salt rejection up to 99.7% when pretreatment, recovery, and temperature follow supplier limits.
Deskripsi Produk
This SWRO 8040 RO membrane is engineered for first-pass seawater desalination, combining high salt rejection with stable flux under standard SWRO test conditions.
This 8.0″ × 40″ thin-film composite (TFC) Membran RO is built for industrial and municipal seawater lines that need high rejection, predictable flux, and compatibility with standard 8040 pressure vessels and interconnectors. It integrates cleanability and preservation guidance so operators can maintain stable product water over the service life.
Key features
- High salt rejection (typical up to 99.7%) for low product conductivity.
- Optimized feed spacer for stable differential pressure and cleaning recovery.
- 1.125″ permeate tube ID; drop-in fit for standard 8040 vessels and couplers.
- Works with staged arrays and energy recovery devices in SWRO trains.
- Supported by approved CIP chemistry dan preservation procedures.
Interfaces & compatibility
- Format: 8040 TFC polyamide element
- Permeate tube: 1.125″ (28.6 mm)
- Vessels/couplers: standard 8″ multi-element pressure vessels with interconnectors
- Change-out: replace like-for-like in most 8040 housings
Operating & cleaning limits*
- Max temperature: 45 °C (113 °F)
- pH range (operation): 2–11; (cleaning): 1–12
- Max pressure: 1,200 psi (8.3 MPa)
- Free chlorine: not recommended on TFC unless the datasheet explicitly allows; dechlorinate upstream
*Always verify the exact limits on the current model datasheet.
Typical test conditions
32,000 mg/L NaCl, 25 °C, ~800 psi, ~8% recovery. In service, performance varies with temperature, salinity, recovery, and pretreatment (SDI/MFI, antiscalant window).
What’s included and Why choose this SWRO 8040 RO membrane
- Factory-preserved element in sealed bag
- Installation & torque notes; cleaning/preservation guidance (download)
Need field criteria? See RO membrane replacement, cleaning & CIPdan troubleshooting matrix.
Parameter Produk
Element size | 8.0″ × 40″ (8040) |
---|---|
Active area | ~37 m² (400 ft²), model dependent |
Typical salt rejection | up to 99.7% (datasheet dependent) |
Rated permeate flow (window) | ~28–34 m³/d (7,500–9,000 gpd) @ 32,000 mg/L, 25 °C |
Permeate tube ID | 1.125″ (28.6 mm) |
Max operating pressure | 1,200 psi (8.3 MPa) |
Max temperature | 45 °C (113 °F) |
pH range | 2–11 operation; 1–12 cleaning |
Test conditions | 32,000 mg/L NaCl; 25 °C; ~800 psi; ~8% recovery |
Values shown are typical for listing purposes; final selection should follow the current model datasheet.For most retrofits, this swro 8040 ro membrane drops into standard 8″ vessels with 1.125″ permeate tubes.
Industri yang Berlaku
- Seawater desalination (first-pass SWRO) for municipalities
- Coastal hotels, island resorts, marine/offshore watermakers
- Industrial process water where seawater feed requires high rejection
Keuntungan Satu
Advantage 1 — High rejection for stable product water
Deliver consistently low product conductivity with robust polyamide selectivity and flow-balanced feed spacers that help control differential pressure across stages.Keuntungan DUA
Advantage 2 — Drop-in 8040 compatibility and serviceability
Standard 1.125″ permeate tube and multi-element vessel coupling enable fast change-outs in existing housings. Supported by clear acceptance criteria after start-up: normalized permeate flow ≥ 90–100% of the clean baseline, rejection at spec, and stage ΔP within limits.Produk Terkait
Produk Terkait
PERTANYAAN YANG SERING DIAJUKAN
T1: Berapa lama sistem reverse osmosis bertahan?
Umur dari sistem reverse osmosis tergantung pada kualitas air dan pemeliharaan. Biasanya, membran bertahan selama 2-3 tahun, sedangkan sistem itu sendiri dapat bertahan lebih dari 10 tahun dengan perawatan yang tepat.
T2: Dapatkah sistem disesuaikan berdasarkan kondisi air yang berbeda?
Ya, semua sistem kami dapat disesuaikan sepenuhnya. Kami menganalisis laporan air dan kebutuhan aplikasi Anda sebelum memberikan solusi yang disesuaikan.
T3: Standar apa yang dipatuhi oleh peralatan STARK?
Produk kami memenuhi CE, ISO 9001, dan dapat dirancang untuk memenuhi peraturan regional atau standar industri tertentu berdasarkan permintaan.
T4: Berapa waktu pengiriman untuk sistem STARK RO?
Sistem standar dikirim dalam waktu 7-15 hari. Untuk pesanan yang disesuaikan, waktu tunggu dapat diperpanjang hingga 20-25 hari tergantung pada kerumitannya.
T5: Apakah Anda menyediakan dukungan teknis atau panduan pemasangan?
Ya. Kami menyediakan dokumentasi teknis lengkap, panduan jarak jauh melalui video, dan dapat mengirimkan teknisi secara internasional berdasarkan permintaan.
T6: Apa saja yang termasuk dalam penawaran Anda?
Kutipan kami mencakup sistem RO lengkap, panel kontrol, pompa, unit pra-perawatan, dan semua perlengkapan yang diperlukan. Alat instalasi dan suku cadang dapat disertakan berdasarkan permintaan.