Oczyszczanie ścieków Century Egg: Bezpieczna neutralizacja solanki pH 14

Spis treści

oczyszczanie ścieków z jaj stulecia4

Century egg wastewater treatment deals with extremely caustic brine (often near pH 14), high salinity, suspended solids, proteins and oil/grease from washing and peeling. This guide explains two proven process trains, safe pH control, design ranges you can bench-test, and what to monitor from start-up to steady state.

Why Century Egg Wastewater Treatment Is Challenging

  • Very high pH from NaOH/Ca(OH)2 marinade — must be neutralized under control (never by dilution).
  • High salinity (brine) — osmotic stress inhibits anaerobic/aerobic biology if the strongest streams are not segregated.
  • Organics — proteins/peptides and marinade residues drive COD/BOD.
  • SS & FOG — shell fines and grease often require front-end clarification or DAF.
century egg wastewater treatment1
century egg wastewater treatment1

Century Egg Wastewater Treatment Process Options

Option 1 — pH Adjustment → Coag/Floc → Anaerobic → Aerobic → Clarification

  1. Equalization (EQ): buffer flows/loads; mixer + level control; conductivity probe recommended.
  2. Neutralization: acid dosing (HCl or food-grade CO2) with dual pH probes and interlocked pumps; target pH 6.8–7.5 before coagulation.
  3. Coagulation/Flocculation: PAC/FeCl3 + polymer; add DAF when FOG is high or quick solids capture is needed.
  4. Anaerobic (UASB/AnMBR): high-rate COD removal and biogas; keep feed salinity within acclimated limits.
  5. Aerobic polishing (A/O, SBR or MBR): close BOD/SS; nitrification if ammonia is present.
  6. Secondary Clarifier / Membrane: achieve solids limit; optional sand/carbon filters for final polishing.

Strengths: low OPEX (biogas credit), good for medium–large flows. Watch-outs: longer HRT, biology needs salinity control.

century egg wastewater treatment2
century egg wastewater treatment2

Option 2 — Brine Segregation Line + Physicochemical Mainstream + Aerobic MBR

  1. Brine-only line: collect the strongest marinade separately; do dedicated neutralization in a small, high-torque tank; controlled blending or partial desalination if TDS remains excessive.
  2. Mainstream line: wash water + light brine → neutralization → coag/floc → DAF.
  3. MBR: compact aerobic polishing with consistent low SS; no separate clarifier required.

Strengths: small footprint, faster start-up, robust to shift changes. Trade-off: higher CAPEX (membranes) and moderate OPEX.

ItemOption 1Option 2
FootprintMedium–largeSmall
Start-up SpeedSlower (seed/acclimation)Fast
Salinity ToleranceNeeds careful controlGood (split-stream)
OPEXLow (biogas credit)Medium

Safe Neutralization of pH-14 Brine

  • Instrumentation: dual pH probes (duty/standby), static or flash mixer, interlocked dosing pumps; high/low pH trips overflow back to EQ.
  • Acid choice: HCl is compact and precise; CO2 is safer and reduces overshoot (forms bicarbonate). Use corrosion-resistant materials and ventilation.
  • Control concept: coarse pH trim in EQ, fine trim in a dedicated neutralization tank just before coag/floc.
  • Safety: reaction is exothermic; add acid to water; provide secondary containment and eyewash/shower as standard EHS practice.

How to Estimate Acid Demand (Titration → Full-Scale)

  1. Take a well-mixed 1 L sample.
  2. Titrate with HCl of known normality to pH 7.0; record the volume used: V_HCl (litres).
  3. For 1.0 N HCl: acid equivalents per litre = V_HCl × 1.0.
  4. Per m³ requirement = (acid equivalents per litre) × 1000. If using 10 N HCl, divide the result by 10 to get litres per m³.

Worked example (step-by-step): A 1 L sample needs 0.20 L of 1.0 N HCl to reach pH 7.0.

Acid equivalents = 0.20 × 1.0 = 0.20 mol/L.
Per m³ = 0.20 × 1000 = 200 mol H⁺ equivalent.
Using 10 N HCl: volume per m³ = 200 ÷ 10 = 20 L/m³.
Add 10–20% control margin; let the PID loop fine-trim.

Note: If you need to convert a supplier’s mass-percent HCl to normality, use the SDS values for wt% and density.
Approximation for HCl (monoprotic): N ≈ (density × wt% × 10) / 36.46 (density in g/mL; wt% as %). Example: 31% HCl at 1.15 g/mL → N ≈ (1.15 × 31 × 10) / 36.46 ≈ 9.8 N.

Typical Design Ranges (Bench-Test Before Final Design)

  • EQ HRT: 6–12 h.
  • Coag/Floc: flash mix \(G·t\) ≈ 300–1000; floc \(G·t\) ≈ 20,000–80,000; optimize by jar tests.
  • DAF: surface loading \( \mathrm{SLR} = Q/A \) = 5–10 m³·m⁻²·h⁻¹; recycle 10–30%.
  • UASB/AnMBR: organic loading \( \mathrm{OLR} = Q \times \mathrm{COD}_{in}/V \) = 1–6 kg COD·m⁻³·d⁻¹; acclimate for salinity.
  • MBR: MLSS 6–12 g·L⁻¹; SRT 12–25 d; monitor TMP and set CIP triggers.
  • Final pH: typically 6–9; COD/BOD/SS to meet your permit or local Standard A/B equivalents.
century egg wastewater treatment3
century egg wastewater treatment3

Operation & Monitoring

  • Online: pH (dual), conductivity (salinity), DO in aerobic tanks, ORP in anaerobic, DAF interface level, MBR TMP.
  • Routine lab: COD, BOD5, SS, oil/grease; record chemical usage and sludge volumes.
  • Sludge: dewater (belt/plate); segregate brine-rich streams for licensed disposal.

FAQ

Do we need a separate tank for the strongest brine?

Yes. Segregation protects biology from salt shock and significantly shortens the overall HRT. A small neutralization tank dedicated to the brine line is best practice.

HCl vs CO₂ — which is better for neutralization?

HCl offers tight control with a small footprint. CO₂ is inherently safer and reduces overshoot; many plants use CO₂ for bulk trim and a small HCl dose for precise setpoint control.

How do we choose between Option 1 and Option 2?

If land is available and long-term OPEX matters most, choose Option 1 with anaerobic energy recovery. If space is tight, flows vary or rapid commissioning is needed, Option 2 with brine split + MBR is preferred.

Engineering Notice (Read Before You Design)

Values above are typical ranges from bench practice. Always verify with titration, jar tests and, where feasible, a small pilot before full-scale design. Do not substitute dilution for treatment. Install dual pH probes, dosing interlocks, ventilation, secondary containment and eyewash/shower per standard EHS practice.

References & Further Reading