SWRO 8040 Membrana RO o wysokim stopniu odrzucenia
SWRO 8040 high-rejection seawater reverse osmosis membrane for first-pass desalination. Rated around 32,000 mg/L NaCl at 25 °C with typical operating pressure near 800 psi. Typical salt rejection up to 99.7% when pretreatment, recovery, and temperature follow supplier limits.
Opis produktu
This SWRO 8040 RO membrane is engineered for first-pass seawater desalination, combining high salt rejection with stable flux under standard SWRO test conditions.
This 8.0″ × 40″ thin-film composite (TFC) RO membrane is built for industrial and municipal seawater lines that need high rejection, predictable flux, and compatibility with standard 8040 pressure vessels and interconnectors. It integrates cleanability and preservation guidance so operators can maintain stable product water over the service life.
Key features
- High salt rejection (typical up to 99.7%) for low product conductivity.
- Optimized feed spacer for stable differential pressure and cleaning recovery.
- 1.125″ permeate tube ID; drop-in fit for standard 8040 vessels and couplers.
- Works with staged arrays and energy recovery devices in SWRO trains.
- Supported by approved CIP chemistry oraz preservation procedures.
Interfaces & compatibility
- Format: 8040 TFC polyamide element
- Permeate tube: 1.125″ (28.6 mm)
- Vessels/couplers: standard 8″ multi-element pressure vessels with interconnectors
- Change-out: replace like-for-like in most 8040 housings
Operating & cleaning limits*
- Max temperature: 45 °C (113 °F)
- pH range (operation): 2–11; (cleaning): 1–12
- Max pressure: 1,200 psi (8.3 MPa)
- Free chlorine: not recommended on TFC unless the datasheet explicitly allows; dechlorinate upstream
*Always verify the exact limits on the current model datasheet.
Typical test conditions
32,000 mg/L NaCl, 25 °C, ~800 psi, ~8% recovery. In service, performance varies with temperature, salinity, recovery, and pretreatment (SDI/MFI, antiscalant window).
What’s included and Why choose this SWRO 8040 RO membrane
- Factory-preserved element in sealed bag
- Installation & torque notes; cleaning/preservation guidance (download)
Need field criteria? See RO membrane replacement, cleaning & CIPoraz troubleshooting matrix.
Parametr produktu
Element size | 8.0″ × 40″ (8040) |
---|---|
Active area | ~37 m² (400 ft²), model dependent |
Typical salt rejection | up to 99.7% (datasheet dependent) |
Rated permeate flow (window) | ~28–34 m³/d (7,500–9,000 gpd) @ 32,000 mg/L, 25 °C |
Permeate tube ID | 1.125″ (28.6 mm) |
Max operating pressure | 1,200 psi (8.3 MPa) |
Max temperature | 45 °C (113 °F) |
pH range | 2–11 operation; 1–12 czyszczenie |
Test conditions | 32,000 mg/L NaCl; 25 °C; ~800 psi; ~8% recovery |
Values shown are typical for listing purposes; final selection should follow the current model datasheet.For most retrofits, this swro 8040 ro membrane drops into standard 8″ vessels with 1.125″ permeate tubes.
Obowiązująca branża
- Seawater desalination (first-pass SWRO) for municipalities
- Coastal hotels, island resorts, marine/offshore watermakers
- Industrial process water where seawater feed requires high rejection
Advantage One
Advantage 1 — High rejection for stable product water
Deliver consistently low product conductivity with robust polyamide selectivity and flow-balanced feed spacers that help control differential pressure across stages.Przewaga DWÓCH
Advantage 2 — Drop-in 8040 compatibility and serviceability
Standard 1.125″ permeate tube and multi-element vessel coupling enable fast change-outs in existing housings. Supported by clear acceptance criteria after start-up: normalized permeate flow ≥ 90–100% of the clean baseline, rejection at spec, and stage ΔP within limits.Powiązane produkty
Podobne produkty
FAQ
P1: Jak długo działa system odwróconej osmozy?
Żywotność systemu odwróconej osmozy zależy od jakości wody i konserwacji. Zazwyczaj membrana wytrzymuje 2-3 lata, podczas gdy sam system może wytrzymać ponad 10 lat przy odpowiedniej pielęgnacji.
P2: Czy system można dostosować do różnych warunków wodnych?
Tak, wszystkie nasze systemy są w pełni konfigurowalne. Analizujemy raporty wodne i potrzeby aplikacji przed dostarczeniem dostosowanych rozwiązań.
P3: Jakie standardy spełnia sprzęt STARK?
Nasze produkty są zgodne z normami CE, ISO 9001, a na życzenie mogą być zaprojektowane tak, aby spełniały określone przepisy regionalne lub normy branżowe.
P4: Jaki jest czas dostawy systemów STARK RO?
Standardowe systemy są wysyłane w ciągu 7-15 dni. W przypadku niestandardowych zamówień czas realizacji może wydłużyć się do 20-25 dni w zależności od złożoności.
P5: Czy zapewniasz wsparcie techniczne lub wskazówki dotyczące instalacji?
Tak. Zapewniamy pełną dokumentację techniczną, zdalne wskazówki za pośrednictwem wideo, a na życzenie możemy wysłać inżynierów za granicę.
P6: Co jest zawarte w wycenie?
Nasza oferta obejmuje kompletny system RO, panel sterowania, pompy, jednostki oczyszczania wstępnego i wszystkie niezbędne elementy. Narzędzia instalacyjne i części zamienne mogą być dołączone na życzenie.