4040 RO Membrane | 4”×40” Reverse Osmosis Element (TFC) | STARK
Nota: Final performance depends on feed quality, temperature and operating pressure. We engineer the element selection to your water analysis and pretreatment.
Descrição do produto
- Stable permeate quality: nominal rejection ≥ 99% on NaCl at 25 °C; smooth surface polyamide for consistent performance.
- Energy flexibility: standard BW elements run ~150–225 psi; LE options target lower pressure at similar flux.
- Serviceability: fits common 4040 vessels; EPDM brine seal; standard 3/4” interconnector ID.
- Designed for pretreatment trains: pair with 20 µm → 5 µm cartridges, carbon/anti-scalant, and UF/clarification as needed to control SDI and biofouling.
Engineering transparency: All ratings are typical and configurable. Guarantees are confirmed against your feed analysis (TDS/SDI, temperature, chlorine, scaling indices) and the selected operating window.
Parâmetro do produto
Technical Parameters (typical values; model-dependent)
Tipo de membrana | Thin-Film Composite (TFC) Polyamide |
---|---|
Element Size | 4.0″ × 40″ (4040), OD ~3.9″, ID 0.75″ |
Active Area | ~7.5–8.5 m² (80–90 ft²), depending on model |
Nominal Salt Rejection | ≥ 99.0% (BW); ≥ 99.2–99.5% for high-rejection variants |
Typical Permeate Flow | ~2,000–2,800 GPD (7.6–10.6 m³/d) at 25 °C, 2,000 ppm NaCl, pH 7, 15% recovery |
Pressão de funcionamento | ~1.0–1.6 MPa (150–225 psi) BW/LE; max 4.1 MPa (600 psi) per model limit |
Feed Water Temperature | 5–45 °C (flux rises with temperature) |
pH Range (continuous / cleaning) | 2–11 / 1–13 |
Free Chlorine Tolerance | 0 mg/L (TFC polyamide is chlorine-sensitive; dechlorinate upstream) |
Max Feed SDI | < 5 recommended; lower for sensitive duties |
Max Pressure Drop (per element) | ≤ 1.0 bar (15 psi) |
Recommended Recovery | 10–20% per pressure vessel (system design-dependent) |
End Connection | Standard 4040 brine seal and interconnector; EPDM O-rings |
Available Variants | BW4040 (high rejection), LE4040 (low energy), FR4040 (fouling-resistant), SW4040 (seawater / higher pressure) |
Test Conditions Note | Unless stated otherwise: 2,000 ppm NaCl, 25 °C, pH 7, 15% recovery; your results vary with temperature and pressure. |
Setor aplicável
- Commercial & light-industrial RO systems for municipal/brackish feeds
- Beverage & bottled water polishing
- Boiler make-up & process water
- Electronics pre-DI / polishing trains
- Wastewater reuse after clarification/UF
- Carwash, HVAC, humidification and rinsing lines
Vantagem Um
Advantage 1 — High Rejection with Flexible Energy Window
- Nominal ≥ 99% salt rejection on NaCl with stable permeate conductivity.
- Low-energy (LE) options to reduce pump pressure and operating cost.
- Fouling-resistant (FR) construction available for difficult feeds.
Vantagem DOIS
Advantage 2 — Easy Retrofit & OEM Support
- Compatible with standard 4040 pressure vessels and adapters.
- OEM/Private label available; documentation and QC traceability provided.
- Application engineering: element selection, pretreatment and dosing guidance based on your water analysis.
Produtos relacionados
Produtos Relacionados
FAQ
Q1: Quanto tempo dura o sistema de osmose inversa?
A vida útil de um sistema de osmose inversa depende da qualidade da água e da manutenção. Normalmente, a membrana dura 2-3 anos, enquanto o sistema em si pode durar mais de 10 anos com os cuidados adequados.
Q2: O sistema pode ser personalizado com base nas diferentes condições da água?
Sim, todos os nossos sistemas são totalmente personalizáveis. Analisamos o seu relatório de água e as necessidades da aplicação antes de fornecer soluções à medida.
Q3: A que normas obedece o equipamento STARK?
Os nossos produtos estão em conformidade com a norma CE, ISO 9001, e podem ser concebidos para cumprir regulamentos regionais específicos ou normas industriais, mediante pedido.
Q4: Qual é o prazo de entrega dos sistemas STARK RO?
Os sistemas standard são enviados no prazo de 7 a 15 dias. Para encomendas personalizadas, o prazo de entrega pode prolongar-se até 20-25 dias, dependendo da complexidade.
Q5: Prestam assistência técnica ou orientação para a instalação?
Sim. Fornecemos documentação técnica completa, orientação remota através de vídeo e podemos enviar engenheiros internacionalmente mediante pedido.
Q6: O que está incluído no vosso orçamento?
O nosso orçamento inclui o sistema RO completo, o painel de controlo, as bombas, as unidades de pré-tratamento e todos os acessórios necessários. As ferramentas de instalação e as peças sobresselentes podem ser incluídas mediante pedido.