
Pompe de circulation STARK TD
Technical parameterFlow range: 4m³/h~1200m³/hLift range: 4.5m~108mTemperature: -15℃~+110°CAPPLICATIONSHVAC systems District heating Industrial cooling systems Water supply systemsFirefighting systems Water treatment systems Other pressure boosting systems Material:cast iron/stainless steel
Description du produit
ubpipipeline circulating pumppeline circulating pumpm pipeline circulating pumpersible pumpSewage treatment equipmentpipeline circulating pumpGuangdong Stark Water Treatment Technology Co., Ltd. is a company that focuses on watertreatment plant and is committed to the research and development, production, sales and after-sales service of environmentally friendly water purification industrial products.The main production and operation of water treatment plant: reverse osmosis system, ultrafiltration system, EDI desalination system, sea water desalination plant, brackish water desalination plant. Products are widely used in electronics, electroplating, power plants, medicine, petroleum, chemical, food and beverage, printing and dyeing indutries. Starck strives to be the forefront explorer of water treatment equipment at home and abroad!Q1: When the middle-opened pump equipped with machine seal needs changing the packing, is the shaft in this pump universal?A: A: Yes, it is universal, but the sealing body, shaft bushing, gland, bolts, fittings and joints must be replaced Q2: Pipe pump is used in the degreasing process before painted, and the shaft seal is often leaking even be replaced for several times. How to solve this problem?A: First of all, confirm leakage part is in the sealing ring or in the sealing ring for corrosion, or in the surface of the friction pair for damage. It is necessary to decide the medium condition of the pump, like whether there are impurities in the medium. Different medium needs corresponding material of corrosion-resisting sealing roller, the medium within impurities grain needs configurating special anti-friction sealing cover.Q3: Where can I see the installation instructions of CDL pump?A: you can find it in the the packing box.Q4: whether the CDL15-10 and CDLF15-10 pump are only different in the base stainless steel, is there any differences in their performance curve?A: CDL (F) series ordinary type and stainless steel type are exactly the same in performance curve.Q5: Is there coupling in CDL15-4 ?A: All CDL(F) series in our company are connected with couplings.Q6: A circulating pump used in our company are seriously leaking. It is unknown whether the pump is come from your company?A: The water pump produced by our company can be judged from three points, 1. Pump invoice number, Q beginning2. Factory number, a total of 10 digits 3. Bar codeQ7: Nowadays, a mechanical seal centrifugal pump is used in playing wastewater use, wastewater containing small molecules of resin, which solidified upon the temperature coming down, which resultedmechanical seal broken down in two days. I would like to ask whether there is a good way to solve this problem.A: Is the machine seal burnt out? If so, it may be caused by the friction burn out due to solidified grease adhering on the gap between the friction pair and preventing circulating water from entering. You can order our special type of knife edge machine seal to solve the problem, thank you.
Paramètres du produit
The Stark Water STARK TD Pipeline Circulating Pump is engineered for efficient and quiet inline liquid circulation. Here are its key technical specifications:
Paramètres | Spécifications / Options de personnalisation |
---|---|
Concentration sur les mots-clés essentiels | pipeline circulating pump design and capabilities. |
Pump Type | Horizontal or Vertical Inline Centrifugal Pump (Single-Stage or Multistage). |
Model Series | STARK TD series (specific model numbers vary by flow/head). |
Matériaux de construction | Pump Casing: Cast Iron (standard), Stainless Steel (SUS304/316 for corrosive liquids/hygiene). Impeller: Stainless Steel, Bronze, or Noryl. Shaft: Stainless Steel. |
Motor Power | Varies by model and head/flow requirements (e.g., 0.37 kW to 75 kW or higher). |
Voltage & Frequency | Single Phase 220V/50Hz or Three Phase 380V/50Hz (customizable for 60Hz/other voltages). |
Flow Rate (Q) | Varies by model (e.g., 5 m³/hr to 1000+ m³/hr). |
Total Head (H) | Varies by model (e.g., 5m to 100m or more), optimized for circulation. |
Pression de fonctionnement max. Pression de fonctionnement | Typically 1.0 MPa (10 Bar) to 2.5 MPa (25 Bar), depending on model and application. |
Inlet/Outlet Size | Flanged connections (PN10/PN16/PN25), sizes from DN25 (1″) to DN300 (12″) or larger. |
Liquid Temperature | Standard: -15°C to 100°C. High-temperature versions up to 120°C or more available. |
Seal Type | Mechanical Seal (e.g., Ceramic/Graphite/SiC) for reliable, leak-free operation. |
Protection Class | IP55 (Motor). |
Insulation Class | F. |
Noise Level | Optimized for low noise emission, particularly beneficial for HVAC applications. |
Installation | Direct inline installation into horizontal or vertical pipelines. |
Industrie concernée
The Stark Water STARK TD Pipeline Circulating Pump is a versatile and essential solution for efficient and quiet liquid circulation across a broad spectrum of industrial, commercial, and residential applications. Its inline design makes it ideal for:
- HVAC Systems: Essential for circulating hot water in heating systems, chilled water in cooling systems, and general water circulation in air conditioning units for commercial buildings, residential complexes, and industrial facilities.
- Hot Water Recirculation: Provides continuous circulation of domestic hot water in large buildings, ensuring instant hot water delivery at faucets and reducing water waste.
- Industrial Process Water Circulation: Circulating various process fluids, cooling water for equipment, and industrial water loops in manufacturing plants, chemical processing, and other industrial settings.
- Water Supply Boosting: Used as an inline booster pump to increase water pressure in specific sections of a pipeline or for smaller-scale water supply systems.
- Fire Fighting Systems (Booster): Can serve as a jockey pump or booster pump to maintain pressure in fire suppression systems.
- Boiler Feed & Condensate Return: Circulating treated water to boilers and handling condensate return in steam systems.
- Agricultural Irrigation: Boosting pressure or circulating water in certain irrigation systems for farms.
- Water Treatment Plants: Used for circulating water within various treatment stages, filter backwash, or transfer between tanks.
- District Heating/Cooling: Integral components in large-scale district energy systems for circulating heated or chilled water.
- General Utility Applications: Any closed-loop system requiring reliable and efficient liquid movement.
Avantage 1
Avantage DEUX
Produits apparentés
Produits similaires
FAQ
Q1 : Quelle est la durée de vie du système d'osmose inverse ?
La durée de vie d'un système d'osmose inverse dépend de la qualité de l'eau et de l'entretien. En règle générale, la membrane dure 2 à 3 ans, tandis que le système lui-même peut durer plus de 10 ans s'il est bien entretenu.
Q2 : Le système peut-il être personnalisé en fonction des différentes conditions de l'eau ?
Oui, tous nos systèmes sont entièrement personnalisables. Nous analysons vos besoins en matière de rapports sur l'eau et d'applications avant de vous proposer des solutions sur mesure.
Q3 : Quelles sont les normes auxquelles répondent les équipements STARK ?
Nos produits sont conformes aux normes CE et ISO 9001 et peuvent être conçus pour répondre à des réglementations régionales spécifiques ou à des normes industrielles sur demande.
Q4 : Quel est le délai de livraison des systèmes STARK RO ?
Les systèmes standard sont expédiés dans un délai de 7 à 15 jours. Pour les commandes personnalisées, le délai peut aller jusqu'à 20-25 jours en fonction de la complexité.
Q5 : Fournissez-vous une assistance technique ou des conseils d'installation ?
Oui. Nous fournissons une documentation technique complète, des conseils à distance par vidéo et nous pouvons envoyer des ingénieurs à l'étranger sur demande.
Q6 : Qu'est-ce qui est inclus dans votre devis ?
Notre devis comprend le système RO complet, le panneau de contrôle, les pompes, les unités de prétraitement et tous les accessoires nécessaires. Les outils d'installation et les pièces de rechange peuvent être inclus sur demande.