
Sistema de filtragem de água de pré-tratamento por osmose inversa Stark 500LPH
Optimize your Reverse Osmosis system’s performance and lifespan with Stark Water’s 500LPH Reverse Osmosis Pretreatment Water Filter System. This comprehensive pretreatment water filter system efficiently removes sediment, chlorine, and hardness, safeguarding your RO membranes and ensuring consistent pure water output for commercial and industrial applications.
Descrição do produto
The longevity and efficiency of any Reverse Osmosis (RO) system are fundamentally dependent on the quality of its feed water. Without proper pre-treatment, RO membranes can quickly foul, scale, or become damaged, leading to costly downtime, frequent replacements, and diminished performance. The Stark Water 500LPH Reverse Osmosis Pretreatment Water Filter System is meticulously engineered to serve as the vital first line of defense, providing comprehensive and reliable conditioning for your RO feedwater.
The Critical Role of a Pretreatment Water Filter System for RO
Our 500LPH reverse osmosis pretreatment water filter system is specifically designed to prepare raw water for the delicate RO membranes. With a capacity of 500 liters per hour, it is ideally suited for small to medium-sized commercial and industrial RO plants. The primary goal of this pretreatment water filter system is to remove contaminants that could otherwise harm the RO membranes. These typically include:
- Suspended Solids & Turbidity: Particles like sand, silt, and rust can physically abrade or clog membrane surfaces.
- Chlorine & Chloramines: These disinfectants can chemically oxidize and irreversibly damage thin-film composite (TFC) RO membranes.
- Hardness (Calcium & Magnesium): These minerals precipitate as scale on the membrane surface, severely reducing water flow and rejection rates.
- Iron & Manganese: Can cause fouling and staining of membranes.
- Organic Matter: Can lead to biological fouling or accumulation on the membrane.
By effectively tackling these issues upstream, our system ensures the RO membranes operate under optimal conditions, maximizing their efficiency and greatly extending their operational lifespan.
Comprehensive Multi-Stage Filtration and Conditioning
The STARK 500LPH reverse osmosis pretreatment water filter system typically incorporates a series of interconnected stages to provide thorough water conditioning:
- Multi-Media Filtration: Often includes sand filters or multimedia filters to effectively remove larger suspended solids, turbidity, and sediment.
- Activated Carbon Filtration: Essential for removing free chlorine, chloramines, organic compounds, unpleasant tastes, and odors, protecting the RO membranes from chemical oxidation.
- Water Softening (Ion Exchange): If the raw water has significant hardness, an automatic water softener is integrated to remove calcium and magnesium ions, preventing scale formation on the RO membranes.
- Anti-scalant Dosing: A chemical dosing system may be included to inject anti-scalant, further inhibiting scale precipitation on the membrane surface, especially for challenging water chemistries or high recovery rates.
- Micron Cartridge Filtration: A final safety filter (e.g., 5-micron) removes any residual fine particulates that might have passed through previous stages, providing absolute protection for the RO membranes.
This integrated approach ensures robust protection and optimal performance for your downstream RO system, translating into consistent pure water output and reduced operational costs.
Parâmetro do produto
Stark Water’s 500LPH Reverse Osmosis Pretreatment Water Filter System is engineered for efficient and reliable RO feedwater conditioning. Here are its key technical specifications:
Parâmetro | Especificação / Opções de personalização |
---|---|
Foco na palavra-chave principal | pretreatment water filter system design and capabilities. |
System Capacity | 500 Liters Per Hour (LPH) / 0.5 m³/hr / approx. 2.2 GPM. Customizable for other capacities. |
Application | Pre-treatment for Reverse Osmosis (RO) systems. |
Typical Stages Included |
|
Filter Tanks Material | FRP (Fiber Reinforced Plastic) or Carbon Steel (lined) for larger units. |
Control Type | Automatic control valves (time-based or flow-based for filters/softeners) for backwash/regeneration. PLC control for comprehensive system automation. |
Inlet Water Requirements | Municipal Water, Well Water, Brackish Water (pre-filtration for various RO types). |
Output Water Quality (to RO) | SDI (Silt Density Index) < 3; Free Chlorine < 0.1 ppm; Hardness < 0.03 mg/L (as CaCO³ if softener is included); Turbidity < 1.0 NTU. |
Operating Pressure | Typically 0.2 – 0.6 MPa (2 – 6 Bar / 29 – 87 PSI). |
Temperatura de funcionamento | 5°C – 45°C (41°F – 113°F). |
Fonte de alimentação | Single Phase 220V AC, 50/60Hz or 3 Phase 380V AC, 50/60Hz (for automatic valves, pumps, dosing systems). |
Construction Materials (Piping) | UPVC, HDPE, or Stainless Steel. |
Dimensões (aproximadas) | Skid-mounted compact design (e.g., L 1500mm x W 700mm x H 1800mm for a typical 500LPH system). |
Certification | Designed to meet relevant industry standards. |
Setor aplicável
Stark Water’s 500LPH Reverse Osmosis Pretreatment Water Filter System is a versatile and essential component for industrial and commercial sectors utilizing RO technology, where effective feedwater conditioning is critical. This pretreatment water filter system is ideal for:
- Commercial & Industrial RO Systems (Small-to-Medium Scale): Providing comprehensive pre-treatment for RO plants used in bottled water production, beverage formulation, food processing, and general industrial process water.
- Hotels & Resorts: Ensuring optimal performance and longevity of RO systems used for drinking water, laundry, and general utility water supply.
- Laboratories & Research Facilities: Pre-treating water for RO systems that supply high-purity water for various lab operations and analytical instruments.
- Hospitals & Clinics: Preparing water for RO systems used in laundries, kitchens, or non-critical applications where high-quality feedwater protects downstream equipment.
- Schools & Educational Institutions: Pre-treating water for RO systems that provide purified drinking water for students and staff.
- Boiler Feed Water Pre-treatment: Conditioning raw water before it enters RO systems, which then feed low to medium pressure boilers, preventing scaling and corrosion.
- Cooling Tower Make-up Water: Pre-filtering water for RO systems used to treat make-up water for cooling towers, reducing mineral buildup and minimizing blowdown.
- Car Washes & Vehicle Detailing: Pre-treating water for RO systems that produce spot-free rinse water, extending the life of RO membranes.
- Agricultural & Horticultural (Specialized): Preparing water for RO systems used in hydroponics or specialized irrigation where precise water quality is essential.
- Small-Scale Manufacturing: Pre-filtering water for RO systems used in specific production processes requiring purified water.
Vantagem Um
Vantagem DOIS
Produtos relacionados
Produtos Relacionados
- Purificador de água para uso doméstico
Aplicações dos pré-filtros de aço inoxidável na filtragem de água
Adicionar ao orçamento - Purificador de água para uso doméstico
STARK 2000L Purificador de água para uso doméstico Caixa de filtro de água com purificador de cartucho de ultrafiltração Pvdf Uf
Adicionar ao orçamento - Purificador de água para uso doméstico
Purificador de água doméstico de osmose reversa alcalina de 75GPD Purificador de água com filtro de água de 5 estágios
Adicionar ao orçamento
FAQ
Q1: Quanto tempo dura o sistema de osmose inversa?
A vida útil de um sistema de osmose inversa depende da qualidade da água e da manutenção. Normalmente, a membrana dura 2-3 anos, enquanto o sistema em si pode durar mais de 10 anos com os cuidados adequados.
Q2: O sistema pode ser personalizado com base nas diferentes condições da água?
Sim, todos os nossos sistemas são totalmente personalizáveis. Analisamos o seu relatório de água e as necessidades da aplicação antes de fornecer soluções à medida.
Q3: A que normas obedece o equipamento STARK?
Os nossos produtos estão em conformidade com a norma CE, ISO 9001, e podem ser concebidos para cumprir regulamentos regionais específicos ou normas industriais, mediante pedido.
Q4: Qual é o prazo de entrega dos sistemas STARK RO?
Os sistemas standard são enviados no prazo de 7 a 15 dias. Para encomendas personalizadas, o prazo de entrega pode prolongar-se até 20-25 dias, dependendo da complexidade.
Q5: Prestam assistência técnica ou orientação para a instalação?
Sim. Fornecemos documentação técnica completa, orientação remota através de vídeo e podemos enviar engenheiros internacionalmente mediante pedido.
Q6: O que está incluído no vosso orçamento?
O nosso orçamento inclui o sistema RO completo, o painel de controlo, as bombas, as unidades de pré-tratamento e todos os acessórios necessários. As ferramentas de instalação e as peças sobresselentes podem ser incluídas mediante pedido.