STARK Stainless Steel Ultrafiltration System (Whole-House, Dual Canister, Auto Backwash)
Stainless steel ultrafiltration system for whole-house tap water treatment. It delivers 0.01–0.02 μm filtration to remove turbidity, bacteria and microplastics while keeping minerals.Whole-house stainless steel Ultrafiltration (UF) system for municipal tap water. 0.01–0.02 μm hollow-fiber membranes remove turbidity, rust, bacteria, cysts and microplastics while keeping minerals. Dual stainless canisters on a compact wheeled frame; easy to install in utility rooms. Automatic backwash & forward flush keep the flux stable and maintenance low. Ideal for kitchens, showers and household drinking pre-treatment. Note: UF does not reduce TDS/fluoride—pair with RO if needed.
Descrição do produto
Stainless Steel Ultrafiltration System Overview
The STARK Stainless Steel Ultrafiltration System is a compact, whole-house solution for municipal tap water. Two stainless UF housings deliver clear, hygienic water to all household taps while preserving beneficial minerals.
How UF Works
UF is a physical barrier process. 0.01–0.02 μm hollow fibers block suspended solids, bacteria and colloids. Periodic backwash/forward flush automatically removes fouling and restores flux.
Key Features
- All-stainless build: SS304 (SS316L optional) housings and rigid frame.
- Auto backwash valve: programmable cycles; manual option available.
- Stable whole-house flow: consistent pressure for kitchens, showers and appliances.
- Food-grade materials with chlorine-tolerant PVDF/PES membranes.
- Easy service: front access, quick drain, lockable casters.
What It Removes / What It Doesn’t
Removes: turbidity, rust, sand/silt, bacteria, protozoa, microplastics, colloids, some organic macromolecules.
Does not remove: dissolved salts, hardness, nitrate or fluoride. For TDS/fluoride reduction, combine with a STARK RO unit at point of use.
Installation & Maintenance
- Install on a level floor near inlet, drain and power. Add a bypass and pressure gauge.
- First start: forward-flush 5–10 minutes until clear.
- Set automatic backwash every 2–3 days (adjust by water quality/use).
- For high turbidity areas, add a 5 μm prefilter upstream.
- Typical membrane life: 24–36 months depending on feed water and maintenance.
What’s Included
Main UF unit with dual stainless housings, automatic valve and gauge, wheeled frame and quick guide. Pre-filters and fittings are optional by order.
Parâmetro do produto
Nominal pore size | 0.01–0.02 μm |
Membrana | PVDF or PES hollow fiber |
Typical flow options | 0.8 / 1.0 / 1.5 / 2.0 m³/h (tap water, 25 °C) |
Operating pressure | 0.15–0.6 MPa (max 0.8 MPa) |
Feed water | Municipal tap water; free chlorine ≤0.5 mg/L; turbidity ≤1 NTU recommended |
Inlet/Outlet | 1″ or 1.5″ |
Valve | Automatic backwash (programmable) or Manual |
Power (auto valve) | AC 110–220 V, 50/60 Hz |
Housing / Frame | SS304 (SS316L optional) |
Drain line | 1/2″–3/4″ recommended |
Approx. size / weight* | 600 × 500 × 1100 mm; 60–85 kg (*to be confirmed) |
Model / SKU | ST-UF-SS2C-10 (1.0 m³/h) • ST-UF-SS2C-15 • ST-UF-SS2C-20 |
Setor aplicável
- Whole-house / villa point-of-entry tap water polishing
- Kitchen drinking water pre-treatment (before RO)
- Small commercial: cafés, office pantries, clinics
- Schools and dormitories with municipal feed
- Residential compounds: lobby or floor-level water supply polishing
Vantagem Um
All-Stainless Hygiene & Durability
Polished SS304/316L housings and a rigid frame deliver corrosion resistance, easy cleaning and a sleek, professional look. Front access and sanitary piping simplify routine service.Vantagem DOIS
Automatic Backwash, Stable Flow
The programmable valve performs backwash and forward flush cycles to remove fouling and keep flux stable, lowering maintenance time and ensuring steady pressure across household taps and appliances.Produtos relacionados
Produtos Relacionados
-
Equipamento de ultrafiltração
STARK suppliers Custom Ultrafiltration water treatment equipment 30T UF System
Adicionar ao orçamento -
Equipamento de ultrafiltração
Chinese suppliers 4T/H Ultrafiltration Equipment 2T/H Reverse Osmosis System for water treatment
Adicionar ao orçamento
FAQ
Q1: Quanto tempo dura o sistema de osmose inversa?
A vida útil de um sistema de osmose inversa depende da qualidade da água e da manutenção. Normalmente, a membrana dura 2-3 anos, enquanto o sistema em si pode durar mais de 10 anos com os cuidados adequados.
Q2: O sistema pode ser personalizado com base nas diferentes condições da água?
Sim, todos os nossos sistemas são totalmente personalizáveis. Analisamos o seu relatório de água e as necessidades da aplicação antes de fornecer soluções à medida.
Q3: A que normas obedece o equipamento STARK?
Os nossos produtos estão em conformidade com a norma CE, ISO 9001, e podem ser concebidos para cumprir regulamentos regionais específicos ou normas industriais, mediante pedido.
Q4: Qual é o prazo de entrega dos sistemas STARK RO?
Os sistemas standard são enviados no prazo de 7 a 15 dias. Para encomendas personalizadas, o prazo de entrega pode prolongar-se até 20-25 dias, dependendo da complexidade.
Q5: Prestam assistência técnica ou orientação para a instalação?
Sim. Fornecemos documentação técnica completa, orientação remota através de vídeo e podemos enviar engenheiros internacionalmente mediante pedido.
Q6: O que está incluído no vosso orçamento?
O nosso orçamento inclui o sistema RO completo, o painel de controlo, as bombas, as unidades de pré-tratamento e todos os acessórios necessários. As ferramentas de instalação e as peças sobresselentes podem ser incluídas mediante pedido.